⭐ Core Definition: Dry-bulb temperature

The dry-bulb temperature (DBT) is the temperature of air measured by a thermometer freely exposed to the air, but shielded from radiation. The dry-bulb temperature is the temperature that is usually thought of as air temperature, and it is the true thermodynamic temperature. It is directly proportional to the mean kinetic energy of the air molecules. Temperature is usually measured in degrees Celsius (°C), Kelvin (K), or degrees Fahrenheit (°F). If expressed in kelvins, then the symbol is Ta, if expressed in Celsius or Fahrenheit, then the symbol is ta. When measuring dry-bulb temperature, care should be taken to prevent the sensor from being subjected to radiation from neighbouring heat sources. To minimize the effects of radiation on the sensor, one could reduce the sensor's emission factor, or reduce the temperature difference between the sensor and the surrounding surfaces, or add a thin ventilated reflective screen.

Unlike wet-bulb temperature, dry-bulb temperature does not indicate the amount of moisture in the air (humidity). The dry-bulb temperature is one of the main inputs for thermal comfort calculations and it is also used for assessing the heat transfer by convection. The dry-bulb temperature is an important variable in psychrometrics, being the horizontal axis of a psychrometric chart.

↓ Menu

>>>PUT SHARE BUTTONS HERE<<<
In this Dossier

Dry-bulb temperature in the context of Thermal comfort

Thermal comfort is the condition of mind that expresses subjective satisfaction with the thermal environment. The human body can be viewed as a heat engine where food is the input energy. The human body will release excess heat into the environment, so the body can continue to operate. The heat transfer is proportional to temperature difference. In cold environments, the body loses more heat to the environment and in hot environments the body does not release enough heat. Both the hot and cold scenarios lead to discomfort. Maintaining this standard of thermal comfort for occupants of buildings or other enclosures is one of the important goals of HVAC (heating, ventilation, and air conditioning) design engineers.

Thermal neutrality is maintained when the heat generated by human metabolism is allowed to dissipate, thus maintaining thermal equilibrium with the surroundings. The main factors that influence thermal neutrality are those that determine heat gain and loss, namely metabolic rate, clothing insulation, air temperature, mean radiant temperature, air speed and relative humidity. Psychological parameters, such as individual expectations, and physiological parameters also affect thermal neutrality. Neutral temperature is the temperature that can lead to thermal neutrality and it may vary greatly between individuals and depending on factors such as activity level, clothing, and humidity. People are highly sensitive to even small differences in environmental temperature. At 24 °C (75.2 °F), a difference of 0.38 °C (0.684 °F) can be detected between the temperature of two rooms.

↑ Return to Menu

Dry-bulb temperature in the context of Cooling tower

A cooling tower is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream, to a lower temperature. Cooling towers may either use the evaporation of water to remove heat and cool the working fluid to near the wet-bulb air temperature or, in the case of dry cooling towers, rely solely on air to cool the working fluid to near the dry-bulb air temperature using radiators.

Common applications include cooling the circulating water used in oil refineries, petrochemical and other chemical plants, thermal power stations, nuclear power stations and HVAC systems for cooling buildings. The classification is based on the type of air induction into the tower: the main types of cooling towers are natural draft and induced draft cooling towers.

↑ Return to Menu

Dry-bulb temperature in the context of Wet bulb temperature

The wet-bulb temperature is the lowest temperature that can be reached under current ambient conditions by the evaporation of water only. It is defined as the temperature of a parcel of air cooled to saturation (100% relative humidity) by the evaporation of water into it, with the latent heat supplied by the parcel. A wet-bulb thermometer indicates a temperature close to the true (thermodynamic) wet-bulb temperature.

More formally, the wet-bulb temperature is the temperature an air parcel would have if cooled adiabatically to saturation at constant pressure by evaporation of water into it, all latent heat being supplied by the parcel. At 100% relative humidity, the wet-bulb temperature is equal to the air temperature (dry-bulb temperature); at lower humidity the wet-bulb temperature is lower than dry-bulb temperature because of evaporative cooling.